Availability: | |
---|---|
Quantity: | |
Differential inputs, voltage
4 internal command values, adjustable and callable
2 internal fixed command values, callable
Control outputs for voltage
Ramp time selection with quadrant recognition
Reverse polarity protection for the operating voltage
Differential inputs, voltage
4 internal command values, adjustable and callable
2 internal fixed command values, callable
Control outputs for voltage
Ramp time selection with quadrant recognition
Reverse polarity protection for the operating voltage
01 | Command value and ramp cards, Analog, Euro-card format | VT-SWKA2-5 |
02 | Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions) | 1X |
03 | Version: standard | V0 |
04 | Option: standard | 0 |
01 | 02 | 03 | 04 | |||
VT-SWKA2-5 | \u2012 | 1X | / | V0 | / | 0 |
01 | Command value and ramp cards, Analog, Euro-card format | VT-SWKA2-5 |
02 | Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions) | 1X |
03 | Version: standard | V0 |
04 | Option: standard | 0 |
01 | 02 | 03 | 04 | |||
VT-SWKA2-5 | \u2012 | 1X | / | V0 | / | 0 |
Component series | 1X | ||
Material number | Data sheet | 1819929059 | |
Type of electronics | Analog | ||
Design | Euro-card |
Operating voltage | Nominal | UB | V | 24 |
Lower limit value | UB(t)min | V | 21 | |
Upper limit value | UB(t)max | V | 40 | |
Current consumption | max. | I | A | 0.35 |
Command value | Voltage | Differential input | Ue | V | \u200b0 \u2026 ±10 |
Differential input resistance | Re | kΩ | 100 | ||
callable, internally generated | Fixed value | V | 10 / -10 | ||
adjustable | V | 0 ... 10 or 0 ... -10 (reference potential is 0 V) |
Call-up internal potentiometer voltages | UE | V | 6 ... 40 (Ri = 2 kΩ, 4 inputs) | |
Ramp time combinations | high for α2 and β2 | 6 ... 40 (Ri = 2 kΩ) | ||
low for α1 and β1 | 695024 | |||
Ramp switch-off | UE | V | 6 ... 40 (Ri = 2 kΩ) |
Voltage | Number and designation | 3 (signal outputs) | ||
Voltage 1) | U | V | \u200b0 \u2026 ±10 |
1) | Imax = 10 mA |
Setting range 1 | Ramp time up/down | t | s | 0,05 \u2026 5 |
Setting range 2 | Ramp time up/down | t | s | 0,1 \u2026 10 |
LED display | Green 1 | Ramp combination α1/β1 | |
Green 2 | Ramp combination α2/β2 | ||
Yellow 1 | 4 command value call-ups P1 ... P4, 2 fixed values | ||
Red | Ramp off | ||
Green/Red | Green: UB ok, red: UB too low |
Anschlussart | 32-pin male connector, DIN 41612, form F | ||
Ambient temperature range | ϑ | °C | \u200b0 \u2026 \u200b70 |
Storage temperature range | ϑ | °C | -20 \u2026 \u200b70 |
Weight | m | kg | 0.33 |
Component series | 1X | ||
Material number | Data sheet | 1819929059 | |
Type of electronics | Analog | ||
Design | Euro-card |
Operating voltage | Nominal | UB | V | 24 |
Lower limit value | UB(t)min | V | 21 | |
Upper limit value | UB(t)max | V | 40 | |
Current consumption | max. | I | A | 0.35 |
Command value | Voltage | Differential input | Ue | V | \u200b0 \u2026 ±10 |
Differential input resistance | Re | kΩ | 100 | ||
callable, internally generated | Fixed value | V | 10 / -10 | ||
adjustable | V | 0 ... 10 or 0 ... -10 (reference potential is 0 V) |
Call-up internal potentiometer voltages | UE | V | 6 ... 40 (Ri = 2 kΩ, 4 inputs) | |
Ramp time combinations | high for α2 and β2 | 6 ... 40 (Ri = 2 kΩ) | ||
low for α1 and β1 | 695024 | |||
Ramp switch-off | UE | V | 6 ... 40 (Ri = 2 kΩ) |
Voltage | Number and designation | 3 (signal outputs) | ||
Voltage 1) | U | V | \u200b0 \u2026 ±10 |
1) | Imax = 10 mA |
Setting range 1 | Ramp time up/down | t | s | 0,05 \u2026 5 |
Setting range 2 | Ramp time up/down | t | s | 0,1 \u2026 10 |
LED display | Green 1 | Ramp combination α1/β1 | |
Green 2 | Ramp combination α2/β2 | ||
Yellow 1 | 4 command value call-ups P1 ... P4, 2 fixed values | ||
Red | Ramp off | ||
Green/Red | Green: UB ok, red: UB too low |
Anschlussart | 32-pin male connector, DIN 41612, form F | ||
Ambient temperature range | ϑ | °C | \u200b0 \u2026 \u200b70 |
Storage temperature range | ϑ | °C | -20 \u2026 \u200b70 |
Weight | m | kg | 0.33 |
Dimensions in mm
Dimensions in mm
Dimensions in mm
Dimensions in mm
The amplifier card may only be unplugged and plugged when de-energized.
The distance to aerial lines, radios and radar systems must be sufficient (>1 m).
Do not lay solenoid and signal lines near power cables.
For signal lines and solenoid conductors, we recommend using shielded cables.
The cable shield must be connected to the control cabinet extensively and as short as possible.
The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.
The amplifier card may only be unplugged and plugged when de-energized.
The distance to aerial lines, radios and radar systems must be sufficient (>1 m).
Do not lay solenoid and signal lines near power cables.
For signal lines and solenoid conductors, we recommend using shielded cables.
The cable shield must be connected to the control cabinet extensively and as short as possible.
The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.