VT-SWKA2-5-1X

Component series 1X
Analog, Euro-card format
For controlling valves with integrated or external electronics
Availability:
Quantity:
sharethis sharing button
  • Differential inputs, voltage

  • 4 internal command values, adjustable and callable

  • 2 internal fixed command values, callable

  • Control outputs for voltage

  • Ramp time selection with quadrant recognition

  • Reverse polarity protection for the operating voltage


01

Command value and ramp cards, Analog, Euro-card format

VT-SWKA2-5


02

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X


03

Version: standard

V0


04

Option: standard

0

01


02


03


04

VT-SWKA2-5

\u2012

1X

/

V0

/

0


General

Component series


1X

Material number

Data sheet


1819929059

Type of electronics


Analog

Design


Euro-card

Voltage supply

Operating voltage

Nominal

UB

V

24

Lower limit value

UB(t)min

V

21

Upper limit value

UB(t)max

V

40

Current consumption

max.

I

A

0.35

Analog inputs

Command value

Voltage

Differential input

Ue

V

\u200b0 \u2026 ±10

Differential input resistance

Re

100

callable, internally generated

Fixed value


V

10 / -10

adjustable


V

0 ... 10 or 0 ... -10 (reference potential is 0 V)

Digital inputs

Call-up internal potentiometer voltages

UE

V

6 ... 40 (Ri = 2 kΩ, 4 inputs)

Ramp time combinations

high for α2 and  β2



6 ... 40 (Ri = 2 kΩ)

low for α1 and  β1



695024

Ramp switch-off

UE

V

6 ... 40 (Ri = 2 kΩ)

Analog outputs

Voltage

Number and designation



3 (signal outputs)

Voltage 1)

U

V

\u200b0 \u2026 ±10
1)Imax = 10 mA

Adjustment options

Setting range 1

Ramp time up/down

t

s

0,05 \u2026 5

Setting range 2

Ramp time up/down

t

s

0,1 \u2026 10

Displays

LED display

Green 1


Ramp combination α1/β1

Green 2


Ramp combination α2/β2

Yellow 1


4 command value call-ups P1 ... P4, 2 fixed values

Red


Ramp off

Green/Red


Green: UB ok, red: UB too low

Other information

Anschlussart



32-pin male connector, DIN 41612, form F

Ambient temperature range

ϑ

°C

\u200b0 \u2026 \u200b70

Storage temperature range

ϑ

°C

-20 \u2026 \u200b70

Weight

m

kg

0.33


4/2 directional seat valve (\u201cY\u201d)

Dimensions in mm

Dimensions in mm


The amplifier card may only be unplugged and plugged when de-energized.

The distance to aerial lines, radios and radar systems must be sufficient (>1 m).

Do not lay solenoid and signal lines near power cables.

For signal lines and solenoid conductors, we recommend using shielded cables.

The cable shield must be connected to the control cabinet extensively and as short as possible.

The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.


Work with Dedication , Serve with Genuineness.
Any Question? Contact our sales team today

COMPANY

PRODUCTS

CONTACT US

WhatsApp: +86 13302251218 
WeChat: suziexie 
Address: Room 501, Building 14, No. 828, Maogang Road, Huangpu District, Guangzhou

LEAVE A MESSAGE

© 2019 Guangzhou Zhiyuan Hydraulic Co.,Ltd. All rights reserved. Site Map   Designed by Growthofficer.cn