Availability: | |
---|---|
Quantity: | |
VT-HACD-DPQ-2X/CMC RETROFIT
Rexroth
R978021618
Actual value recording via SSI encoder, incremental or analog position measurement system possible
Free configuration of the valve control spool
Control loop adjustment
Jog mode controlled
Separate menus for injection, holding pressure and back pressure
Pressure transition via:
- Position
- Internal mold pressure
- Hydraulic pressure via position
- Discrete input
Enable input and OK output
±10 V reference voltage output
Front display with keys to display and change parameters as well as for diagnosis purposes.
RS232 serial interface
Up to 32 controller cards can be interconnected for parameterization and diagnosis via the local bus
internal or analog profile
I/O configuration
Actual value recording via SSI encoder, incremental or analog position measurement system possible
Free configuration of the valve control spool
Control loop adjustment
Jog mode controlled
Separate menus for injection, holding pressure and back pressure
Pressure transition via:
- Position
- Internal mold pressure
- Hydraulic pressure via position
- Discrete input
Enable input and OK output
±10 V reference voltage output
Front display with keys to display and change parameters as well as for diagnosis purposes.
RS232 serial interface
Up to 32 controller cards can be interconnected for parameterization and diagnosis via the local bus
internal or analog profile
I/O configuration
01 | 02 | 03 | 04 | 05 | 06 | 07 | ||||||
VT-HACD-DPQ | \u2013 | 1 | \u2013 | 2X | / | V0 | / | 1 | \u2013 | \u2013 | 0 |
01 | Digital controller card | VT-HACD-DPQ |
02 | One axis | 1 |
03 | Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) | 2X |
04 | Basic unit | V0 |
05 | With display | 1 |
06 | Without bus connection | 0 |
CANopen | C | |
DeviceNet | D | |
07 | Without valve output stage | 0 |
01 | 02 | 03 | 04 | 05 | 06 | 07 | ||||||
VT-HACD-DPQ | \u2013 | 1 | \u2013 | 2X | / | V0 | / | 1 | \u2013 | \u2013 | 0 |
01 | Digital controller card | VT-HACD-DPQ |
02 | One axis | 1 |
03 | Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) | 2X |
04 | Basic unit | V0 |
05 | With display | 1 |
06 | Without bus connection | 0 |
CANopen | C | |
DeviceNet | D | |
07 | Without valve output stage | 0 |
Component series | 2X |
Operating voltage | UB | 24 VDC | ||
Operating voltage | Lower limit value | UB(t)min | V | 21 |
Upper limit value | UB(t)max | V | 30 | |
Current consumption | Imax | 150 mA | ||
Fuse | IS | 4 A time-lag |
Number | 6 | |||
Voltage inputs | Range | U | 0 to 10 V or ±10 V (configurable) | |
Input resistance | Re | 100 kΩ, > 10 MΩ for input AI 1 | ||
Resolution | 5 mV for range ±10 V, 2.5 mV for range 0...10 V | |||
Non-linearity | mV | < 10 | ||
Current inputs | Range | I | 0...20 mA or 4...20 mA (configurable) | |
Input resistance | Re | 100 Ω | ||
Leakage current | Iv | 0.15 % (with 500 Ω between pin AI x- and 0 V) | ||
Resolution | 5 μA |
Signal | log 0 | 0 to 5 V | |
log 1 | 16 V to UB |
Number | 3 | |||
AO1 voltage output | Output voltage | U | 0 to 10 V or ±10 V (configurable) | |
Current, max. | Imax | mA | 10 | |
Load, min. | RLmin | kΩ | 1 | |
Resolution | 1.25 mV (14 bit) | |||
Residual ripple | ±15 mV (without noise) | |||
AO1 current output | Current | I | 0...20 mA or 4...20 mA (configurable) | |
Load, max. | Rmax | Ω | 500 | |
Resolution | 1.25 μ | |||
Residual ripple | ±15 µA (without noise) | |||
AO2/AO3 voltage output | Output voltage | U | ±10 V | |
Current, max. | Imax | mA | 10 | |
Load, min. | RLmin | kΩ | 1 | |
Resolution | 10 mV (11 bit) | |||
Residual ripple | ±25 mV (without noise) |
Number | 8 | |||
Logic level | log 0 (low) ≤ 2 V; log 1 (high) ≤ UB; Imax = 20 mA, maximum load capacity C = 0.047 μF | |||
Connection | flexible conductor up to 1.5 mm2 | |||
Reference potential for all signals | GND | |||
Signal | log 0 | 0 to 5 V | ||
log 1 | 16 V to UB | |||
Current, max. | Imax | mA | 30 |
SSI transducer | Line receiver/driver | RS485 |
Reference voltage | U | V | ± 10 |
Load, max. | Imax | mA | 30 |
Residual ripple | mV | < 20 | |
Scanning time | t | ms | 2 |
Interface, serial | RS 232 (front plate), D-Sub socket | ||
Anschlussart | 64-pin male connector, DIN 41612, form G | ||
Local bus, distance to the furthermost device, max. | I | max. 280 m line length | |
Operating temperature range | ϑ | °C | \u200b0 \u2026 +50 |
Storage temperature range | ϑ | °C | -20 \u2026 +70 |
Weight | m | g | 0.2 |
Component series | 2X |
Operating voltage | UB | 24 VDC | ||
Operating voltage | Lower limit value | UB(t)min | V | 21 |
Upper limit value | UB(t)max | V | 30 | |
Current consumption | Imax | 150 mA | ||
Fuse | IS | 4 A time-lag |
Number | 6 | |||
Voltage inputs | Range | U | 0 to 10 V or ±10 V (configurable) | |
Input resistance | Re | 100 kΩ, > 10 MΩ for input AI 1 | ||
Resolution | 5 mV for range ±10 V, 2.5 mV for range 0...10 V | |||
Non-linearity | mV | < 10 | ||
Current inputs | Range | I | 0...20 mA or 4...20 mA (configurable) | |
Input resistance | Re | 100 Ω | ||
Leakage current | Iv | 0.15 % (with 500 Ω between pin AI x- and 0 V) | ||
Resolution | 5 μA |
Signal | log 0 | 0 to 5 V | |
log 1 | 16 V to UB |
Number | 3 | |||
AO1 voltage output | Output voltage | U | 0 to 10 V or ±10 V (configurable) | |
Current, max. | Imax | mA | 10 | |
Load, min. | RLmin | kΩ | 1 | |
Resolution | 1.25 mV (14 bit) | |||
Residual ripple | ±15 mV (without noise) | |||
AO1 current output | Current | I | 0...20 mA or 4...20 mA (configurable) | |
Load, max. | Rmax | Ω | 500 | |
Resolution | 1.25 μ | |||
Residual ripple | ±15 µA (without noise) | |||
AO2/AO3 voltage output | Output voltage | U | ±10 V | |
Current, max. | Imax | mA | 10 | |
Load, min. | RLmin | kΩ | 1 | |
Resolution | 10 mV (11 bit) | |||
Residual ripple | ±25 mV (without noise) |
Number | 8 | |||
Logic level | log 0 (low) ≤ 2 V; log 1 (high) ≤ UB; Imax = 20 mA, maximum load capacity C = 0.047 μF | |||
Connection | flexible conductor up to 1.5 mm2 | |||
Reference potential for all signals | GND | |||
Signal | log 0 | 0 to 5 V | ||
log 1 | 16 V to UB | |||
Current, max. | Imax | mA | 30 |
SSI transducer | Line receiver/driver | RS485 |
Reference voltage | U | V | ± 10 |
Load, max. | Imax | mA | 30 |
Residual ripple | mV | < 20 | |
Scanning time | t | ms | 2 |
Interface, serial | RS 232 (front plate), D-Sub socket | ||
Anschlussart | 64-pin male connector, DIN 41612, form G | ||
Local bus, distance to the furthermost device, max. | I | max. 280 m line length | |
Operating temperature range | ϑ | °C | \u200b0 \u2026 +50 |
Storage temperature range | ϑ | °C | -20 \u2026 +70 |
Weight | m | g | 0.2 |
Dimensions in mm
Dimensions in mm
The amplifier card may only be unplugged and plugged when de-energized.
The distance to aerial lines, radios and radar systems must be sufficient (>1 m).
Do not lay solenoid and signal lines near power cables.
For signal lines and solenoid conductors, we recommend using shielded cables.
The cable shield must be connected to the control cabinet extensively and as short as possible.
The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.
The amplifier card may only be unplugged and plugged when de-energized.
The distance to aerial lines, radios and radar systems must be sufficient (>1 m).
Do not lay solenoid and signal lines near power cables.
For signal lines and solenoid conductors, we recommend using shielded cables.
The cable shield must be connected to the control cabinet extensively and as short as possible.
The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.